How we grade air. The tier names Good, Moderate and Poor are borrowed from the European Air Quality Index. The threshold values come from GOAQS, which has three tiers (Good, Moderate, Unhealthy). We call its Unhealthy tier Poor.

Severe is ours. GOAQS stops at 26 µg/m³ of PM2.5, and the European index only reaches its top band at 140. Neither separates an unpleasant reading from a dangerous one, so we added Severe to make that difference unmistakable.

Thresholds

Each pollutant is graded on its own scale. PM2.5 and CO₂ follow GO IAQS Score breakpoints. GO IAQS publishes two tiers of limits, Starter and Ultimate, and the comparison at the bottom of this page shows both.

VOC and NOx use the Sensirion index, which runs from 1 to 500. The VOC index is a relative score, not a concentration like TVOC in ppb: 100 is the sensor's recent average, so it shows how air is changing in your space.

MetricGoodModeratePoorSevereBasis
PM2.5 µg/m³0–1011–2526–140140+GO IAQS Score breakpoints · Severe added by ambient
CO₂ ppm400–800801–1,4001,401+–GO IAQS Score breakpoints
VOC index OptionalSensirion index1–150151–250251–450451+Sensirion VOC Index
NOx index OptionalSensirion index1–2021–100101–400401–500Sensirion NOx Index

Shown, but not scored

  • PM1.0, PM4.0 and PM10 — measured and shown on your dashboard for context. They are not used in the score.

Temperature and humidity

These are not pollutants, so they are graded on a comfort scale instead of Good to Severe.

Metric Discomfort Slight discomfort Comfort Slight discomfort Discomfort Basis
Temperature°C below 16 16–20 20–26 26–29 above 29 ISO 7730, ASHRAE 55, WHO
Humidity% RH below 20 20–40 40–60 60–70 above 70 WHO, ASHRAE, REHVA

Noise

Noise is graded the same way as pollutants: the lower the reading, the better. These bands are a draft and have not been confirmed.

MetricGoodModeratePoorSevereBasis
NoisedB(A)below 3535–5555–7070+DRAFT · WHO, EPA (to confirm)

Indoor background noise measured in A-weighted decibels. Lower is better. 35 dB(A) is the WHO guideline level for quiet bedrooms and classrooms.

Air quality score

Your overall air quality score runs from 0 to 10, where 10 is the cleanest air. It uses the GOAQS calculation, applied to the pollutants in the table below.

Concentration of each pollutant in each air quality score band
Pollutant Good Score 10–8 Moderate Score 7–4 Poor Score 3–1 Severe Score 0
PM2.5 µg/m³0–1011–2526–140140+
CO₂ ppm400–800801–1,4001,401+–

VOC and NOx are not part of the GO IAQS score, so they are left out of it by default. In ambient you can choose to add them to your own score, or remove them again.

How is the score calculated?

Calculation method: GO IAQS Score from GO AQS.

Each pollutant is scored on its own, from 0 to 10.

The lowest of those scores is your overall score, so the worst pollutant decides it.

I = 10 − ( Ihigh − IlowChigh − Clow × ( C − Clow ) + Ilow )
I
Air quality score, 0–10 (10 is the cleanest air)
C
The measured concentration of the pollutant
Clow, Chigh
The concentration breakpoints of the band the reading falls in
Ilow, Ihigh
The index values that match those breakpoints

Within a tier, a reading is placed proportionally between that tier's two breakpoints. GO IAQS's index values (I) run from 0 to 10 and are subtracted from 10: Good covers I of 0–2 (score 10–8), Moderate 3–6 (score 7–4) and Unhealthy 7–10 (score 3–0).

ambient splits GO IAQS's Unhealthy band into Poor (score 3–1) and Severe (score 0).

Example. PM2.5 of 18 µg/m³ falls in Moderate: C low = 11, C high = 25, I low = 3, I high = 6.

I = 10 − ( (6 − 3) ÷ (25 − 11) × (18 − 11) + 3 ) = 10 − 4.5 = 5.5

Why indices use different words

There is no single standard for naming air quality levels. Indices differ in how many tiers they have, what the tiers are called, and where each one starts.

Ambient uses the European index's plain wording (Good, Moderate, Poor), keeps GOAQS's three-tier structure and thresholds, and adds Severe on top.

How do the tier names compare?
Tier names used by each air quality index
Index Tier names Tiers Top band ends at (PM2.5) Notes
ambient Good · Moderate · Poor · Severe 4 10 GOAQS values with European-style names, plus Severe added by ambient.
GO IAQS Score Good · Moderate · Unhealthy 3 10 Our Poor tier is GOAQS's Unhealthy tier, renamed.
European Air Quality Index (EEA) Good · Fair · Moderate · Poor · Very poor · Extremely poor 6 5 Where our Good, Moderate and Poor wording comes from. We don't use its cut-offs.
US EPA AQI Good · Moderate · Unhealthy for sensitive groups · Unhealthy · Very unhealthy · Hazardous 6 9 Names refer to health effects, and include a band for sensitive groups.
UK DAQI Low · Moderate · High · Very high 4 groups over 10 numbers 11 (index 1) Words describe how much pollution there is. The numbers 1–10 add detail.
WHO 2021 guidelines Guideline level + interim targets 1–4 5 levels 15 (24-hour guideline) Not a labelled index. It sets limits to aim for.

The reasoning behind each

  • European index (EEA). The Good and Fair bands are based on WHO's 2021 guideline levels. The higher bands are rounded to EU alert and information levels, so the names run from a health guideline up to a legal warning. The overall result is the poorest level of any pollutant. EEA methodology
  • US EPA. Category names describe the health effect. "Unhealthy for Sensitive Groups" was added in 1999 because focus groups understood that "sensitive groups" does not mean the general public. EPA made that band orange, not red, because red would overstate the risk for most people and could cost the index its credibility. EPA 1999 rule
  • WHO. WHO publishes guideline levels, not named tiers. It added interim targets as stepping stones for places far above the guideline, and the guidelines are not legally binding. WHO Q&A

Same word, different limit. "Good" for PM2.5 ends at 5 µg/m³ in the European index, 9 in the US EPA index, 10 in GOAQS (and ambient) and 11 in the UK's first band. When you compare indices, compare the numbers, not the names.

Compare with other indices

Other countries and organisations grade air differently. Pick an index to see its PM2.5 and PM10 bands.

ambient (GOAQS-based)

The scale used on this page. GOAQS thresholds with Severe added on top.

TierScorePM2.5 (µg/m³)CO₂ (ppm)
Good8–100–10400–800
Moderate5–711–25801–1,400
Poor1–426–1401,401+
Severe0140+–

GO IAQS: Starter and Ultimate tiers

GO IAQS has two tiers of limits. Starter covers PM2.5 and CO₂ and is meant for low-cost sensors. Ultimate adds ozone, CO, formaldehyde, NO₂ and radon and is stricter. The 0–10 Score has its own breakpoints, shown in the last row.

TierPM2.5 (µg/m³)CO₂ (ppm)Pollutants covered
Starter25 (24-hour)1,000 (24-hour)PM2.5, CO₂
Ultimate15800PM2.5, CO₂, ozone, CO, formaldehyde, NO₂, radon
Score: Good / Moderate / Unhealthy0–10 / 11–25 / 26–100450–800 / 801–1,400 / 1,401–5,000PM2.5, CO₂, CO, formaldehyde, ozone, NO₂, radon

Source

European Air Quality Index (EEA)

Six bands, concentrations in µg/m³. Ambient borrows its Good / Moderate / Poor wording, but not these cut-offs.

BandPM2.5 (µg/m³)PM10 (µg/m³)
Good0–50–15
Fair6–1516–45
Moderate16–5046–120
Poor51–90121–195
Very poor91–140196–270
Extremely poorabove 140above 270

Source

US EPA AQI (24-hour)

Six categories, concentrations in µg/m³, 24-hour average.

CategoryPM2.5 (µg/m³)PM10 (µg/m³)
Good0–90–54
Moderate9.1–35.455–154
Unhealthy for sensitive groups35.5–55.4155–254
Unhealthy55.5–125.4255–354
Very unhealthy125.5–225.4355–424
Hazardous225.5+425+

Source

UK Daily Air Quality Index (DAQI)

Ten index values grouped into Low, Moderate, High and Very high. Concentrations in µg/m³.

IndexBandPM2.5 (µg/m³)PM10 (µg/m³)
1Low0–110–16
2Low12–2317–33
3Low24–3534–50
4Moderate36–4151–58
5Moderate42–4759–66
6Moderate48–5367–75
7High54–5876–83
8High59–6484–91
9High65–7092–100
10Very high71+101+

Source

WHO 2021 air quality guidelines (24-hour)

Health-based guideline levels and interim targets, µg/m³, 24-hour average. These are guidelines, not an index.

LevelPM2.5 (µg/m³)PM10 (µg/m³)
Air quality guideline1545
Interim target 42550
Interim target 337.575
Interim target 250100
Interim target 175150

Source

GO IAQS Ultimate tier

GO IAQS has two tiers of limits. This page uses the Starter tier's pollutants (PM2.5 and CO₂). The Ultimate tier is stricter and health-protective. It sets limits for PM2.5 (15 µg/m³), CO₂ (800 ppm), ozone, carbon monoxide, formaldehyde (27 ppb), nitrogen dioxide and radon.

See the full table, with averaging periods and footnotes, on the GO IAQS Limits page.

Noise levels Coming soon

Noise monitoring is not part of ambient one today and is not included in the air quality score. If it would be useful to you, get in touch. Noise is measured differently from air pollutants: official limits are occupational exposures in dB(A), averaged over a working day, so they do not map onto Good / Moderate / Poor / Severe. The levels below are workplace hearing-protection references, not indoor comfort bands.

SourceLevelWhat it means
CDC / NIOSH85 dBA, 8-hour averageRecommended exposure limit. Every 3 dB increase halves the time: 88 dBA for 4 h, 91 dBA for 2 h, 94 dBA for 1 h
CDC / NIOSHImpulsive noise 140 dBPeak limit for sudden loud sounds
HSE (Great Britain)Lower action value: 80 dB(A), peak 135 dB(C)Employer must assess risk and provide information and training
HSE (Great Britain)Upper action value: 85 dB(A), peak 137 dB(C)Employer must reduce exposure and provide hearing protection
HSE (Great Britain)Exposure limit: 87 dB(A), peak 140 dB(C)Must not be exceeded, with hearing protection taken into account

Rule of thumb from the CDC: if you have to raise your voice to be heard at arm's length, the noise may be hazardous. NIOSH's 85 dBA is a recommendation; the legal limit in the US (OSHA) is 90 dBA, while the HSE values are UK law for workplaces (Control of Noise at Work Regulations 2005).